Controls 12 V/AC motors (even DC motors with an upstream rectifier), light bulbs, heaters, etc. Only for operation on a 12 V/AC transformer (50 - 60 Hz), not for DC (Battery). By replacing the potentiometer, it is possible to regulate voltages such as 24 V/AC or 48 V/AC.
Operating voltage 12 V/AC, 50 - 60 Hz (only for conventional iron-core transformers, not electronic transformers)
If the enclosed potentiometer is replaced by 100-K-lin potentiometer, you can also regulate 24 V/AC, or a 220-K-lin potentiometer is required for 48 V/AC (not included)
Operating principle phase control
Control range approx. 0 - 90%
Load capacity for ohmic and inductive loads up to 10 A (for cooling) or max 4 A without additional cooling e.g. AC motors, light bulbs, heaters, transformers, etc.
Dimensions approx. 87 x 60 x 33 mm (with fastening base)