The Fluke 1507 and 1503 insulation testers are handy, robust, reliable and easy to use.
Since they have multiple test voltages, they are ideal for troubleshooting, set-up and preventative maintenance.
• Insulation testing range: 0.01 Mohm to 10 Gohm• Insulation testing voltages: 50 V, 100 V, 250 V, 500 V, 1000 V• Automatic calculation of the polarisation index and dielectric absorption level• With the Compare function (good/bad) repetitive tests can be performed quickly and easily• A probe with release button makes repetitive tests or tests on hard-to-reach objects easier• Detection of live circuits prevents insulation tests at voltages over 30 V and thus increases the protection of the user• Automatic discharge of capacitive voltages for higher protection for the user• AC/DC voltage: 0.1 V to 600 V• 200 mA continuity• Resistance: 0.01 ohm - 20.00 kohm• Automatic shut-off to save battery power• Large backlit display for easy reading of measurements• Overvoltage category CAT IV 600 V for increased protection of the user• Probe with release button, test leads, test probes and crocodile clips included• Mounting options for the optional magnet holder Fluke TPAK for hands-free operation• Four alkaline batteries type AA (NEDA 15 A or IEC LR6) for more than 1000 insulation testsIncluded with deliveryTP165x slim probe with release buttonTL224 SureGrip silicon test lead setTP74 probes with pointed 4 mm banana plugsCrocodile clipsUser manual4 AA batteriesAC and DC voltage measurementInaccuracyRange: 600.0 VResolution: 0.1 V50 Hz to 400 Hz ± (% of MW + digits) ±(2% + 3)Input impedance: 3 Mohm (nominal), < 100 pFCommon-mode rejection ratio (1 kohm unbalanced): > 60 dB at DC, 50 Hz or 60 HzOverload protection: 600 V effective or DCProtective conductor resistance measurementRange/resolution: 20.00 ohm 0.01 ohm200.
0 ohm 0.1 ohm2000 ohm 1.0 ohm20.
00 kohm 0.01 kohmInaccuracy: ±(1.5% + 3)Overload protection: 2 V effective or DCIdle test voltage: > 4.0 V, < 8 VShort-circuit current: > 200.0 mAMeasuring and test functionsMeasuring range: 0.01 Mohm to 10 GohmTest voltages: 50 V, 100 V, 250 V, 500 V, 1000 VInaccuracy of the test voltage: + 20%, - 0%Short-circuit current: 1 mA nominalAutomatic discharge: discharge time < 0.5 seconds at C = 1 µF or lessDisplay for power circuit: prevents the test if external voltage before the beginning of the tests > 30 VMaximum capacitive load: can be operated with up to 1 µF loadInaccuracy when measuring:50 V: ±(3% + 5)100 V: ±(3% + 5)250 V: ±(1.5% + 5)500 V: ±(1.5% + 5)1000 V: ±(1.5% + 5) up to 2000 Mohm, ±(10% + 3) over 2000 Mohm

Relevant Products

Loading...