JUMPFLEX® measuring transducer
Isolating amplifier, permanently set for current signals or voltage signals
Brief description:
The pre-configured isolating amplifiers convert analogue standard signals and amplify, filter and galvanically isolate the analogue standard signals from one another.
The devices have a 3-way isolation with a test voltage of 2.5 kV. Isolating amplifier 857-411 isolates analogue current signals in the range of 0(4) ... 20 mA in the input to 0(4) ... 20 mA in the output.
Isolating amplifier 857-412 isolates analogue voltage signals in the range of 0(2) ... 10 V in the input to 0(2) ... 10 V in the output. The supply voltage for the device, which can be bridged quickly and cost-effectively via side push-in type jumper bars, is 24 V DC. A green LED on the front of the device signals that it is in operation. The isolating amplifiers meet the requirements of safe isolation as per EN 61140 with a test voltage of 2.5 kV between input/output/supply.
Dimensions (mm) W x H x D: 6 x 96 x 94 (height from the top edge of the mounting rail)
Connection technology: CAGE CLAMP®S
Single-wire cross-sections: 0.08 mm² ... 2.5 mm²/AWG 28 ... 12
Fine-stranded cross-sections: 0.34 mm² ... 2.5 mm²/AWG 22 ... 12
Insulation stripping lengths 9 ... 10 mm/0.37 in
Input signal: 0(4) ... 20 mA (857-411), 0(2) ... 10 V (857-412)
Input resistance: 50 O, 100 kO
Output signal: 0(4) ... 20 mA (857-411), 0(2) ... 10 V (857-412)
Apparent ohmic resistance: 600 O (857-411), 2 kO (857-412)
Limit frequency: 100 Hz
Time setting (T10 - 90): < 3.5 ms
Supply voltage: UN DC 24 V
Supply voltage range: 16.8 V ... 31.2 V
Power consumption at 24 V DC: < 25 mA
Transmission error: < 0.1 % from end value
Temperature coefficient: 0.01 %/K
Test voltage (input/output/supply): 2.5 kV AC, 50 Hz, 1 min.
Ambient temperature: -25°C ... +70°C
Storage temperature: -40°C ... +85°C